Practice of Waste Heat Recovery and Energy-saving Transformation of Setting Machine

Updated: 10/27/2017 11:48:49 AM

Abstract: This paper introduces the implementation measures of waste heat recovery and energy-saving transformation of setting machine. The energy-saving effect of steam condensate recovery is also studied. The results show that the average temperature of the steam condensate collected from setting machine is 79.8 ℃, and the average temperature of the water in boiler storage tank is 26.0 ℃. This transformation can save 2 015.1 t standard coal every year, and has good energy-saving effect.


Key words: setting machine; steam condensate; waste heat recovery; energy-saving transformation; amount of energy saving


Authority in Charge: China National Textile and Apparel Council (CNTAC)

Sponsor :China Textile Information Center (CTIC)

ISSN 1003-3025 CN11-1714/TS

CTL